title: "smartCUE-three"
canonical: "https://docs.cuesystem.com/space/CVCHELP/524353620/smartCUE-three"
format: markdown
---
> Macro (toc)

---

# **smartCUE-three-wifi**

# Properties

- **IP address **of the smartCUE-three unit defaults to 192.168.1.254
- **TCP Port 1** is the number of TCP port connected to TcpClient1Connector, defaults to 10001
- **TCP Port 2** is the number of TCP port connected to TcpClient2Connector, defaults to 10002
- **UDP Port ** is the number of UDP port connected to UdpClientConnector, defaults to 7777
- All properties (IP address, ports) must match values set in the Admin Web of the smartCUE unit.
- All TCP/UDP ports must be enabled in router/firewall settings.

# Connection

The specific smartCUE driver is located in the CUEdevice folder. Insert the driver into *MyProject Resouces/ CUEunits and devices*, then drag and drop this driver to project configuration.

Connect all smartCUE interface connectors to appropriate channels on CUEunit (see the example below, where the name of the smartCUE unit is Interface1).

You can connect any serial (Digital IO, General IO, Ir) driver to the Serial (DigitalIO, General IO, Ir) channels of the smartCUE unit (see the example below, where names of the receiver's serial driver and TV's Ir driver are AV_Receiver1 and TV1).

Example of a connection in a Composer's Configuration window:

![image](media://24eb45c1-a65b-4305-ae32-6e33eb867ae6)

# **DigitalIO channel commands**

# Close

This command works the same way as _DigitalIO command  Close.

# ClosePulse

This command works the same way as the _DigitalIO command  ClosePulse.

# IsClosed

This command works the same way as the _DigitalIO command IsClosed.

# Open

This command works the same way as the _DigitalIO command Open.

# WaitWhileClosed

This command works the same way as the _DigitalIO command WaitWhileClosed.

# WaitWhileOpened

This command works the same way as _DigitalIO command WaitWhileOpened.

# **Serial channel commands**

# ClearReceiveBuffer

This command works the same way as _Serial command ClearReceiveBuffer.

# Receive

This command works the same way as the _Serial command Receive.

# ReceiveAppend

This command works the same way as the _Serial command ReceiveAppend.

# ReceiveFPacket

This command works the same way as the _Serial command ReceiveFPacket.

# ReceiveHFPacket

This command works the same way as the _Serial command ReceiveHFPacket.

# ReceiveHLPacket

This command works the same way as the _Serial command ReceiveHLPacket.

# ReceiveSyncFrame

This command works the same way as the _Serial command ReceiveSyncFrame.

# Send

This command works the same way as _Serial command Send.

# SetSerialParameters

The function sets the communication parameters of the serial channel.

#### Syntax

```visualbasic
Function SetSerialParameters(
  mode As Byte,
  bitspersecond As Long,
  databits As Byte,
  parity As Byte,
  stopbits As Byte,
  flowcontrol As Byte,
  ParamArray)
As Boolean
```

#### Parameters

mode

Byte It is the mode of the channel. Predefined constants for parameter mode are as follows:

|  |  |  |
| --- | --- | --- |
| Name | Value | Description |
| _SERIAL_MODE_RS232 | 0 | Channel is in RS232 mode. |

bitspersecond

Long Following baudrates can be used: 300, 600, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400, 460800.

databits

Byte It is the number of data bits from 7 to 8.

parity

Byte It is the type of parity. Predefined constants for parameter parity are as follows:

|  |  |  |
| --- | --- | --- |
| Name | Value | Description |
| _SERIAL_PARITY_NO | 0 | No parity. |
| _SERIAL_PARITY_ODD | 1 | Odd parity. |
| _SERIAL_PARITY_EVEN | 2 | Even parity. |

stopbits

Byte It is the number of stop bits. Predefined constants for parameter stopbits are as follows:

|  |  |  |
| --- | --- | --- |
| Name | Value | Description |
| _SERIAL_STOPBITS_ONE | 0 | One stop bit. |
| _SERIAL_STOPBITS_TWO | 2 | Two stop bits. |

flowcontrol

Byte It is the type of control. Predefined constants for parameter flowcontrol are as follows:

|  |  |  |
| --- | --- | --- |
| Name | Value | Description |
| _SERIAL_FLOWCONTROL_NONE | 0 | No handshake. |
| _SERIAL_FLOWCONTROL_RTSCTS | 1 | Hardware flow control RTS/CTS. |
| _SERIAL_FLOWCONTROL_XONXOFF | 2 | Software flow control by XON and XOFF bytes. Standard values XON=&h11 and XOFF=&h13 are used. |

ParamArray

It is not used in this function. It is there just to maintain compatibility with _Serial command SetSerialParameters.

#### Return Value

Boolean It is True on success or False if an error occurs.

#### Examples

Channel S1 is in RS232 mode, with 9600 bits per second, 8 data bits, no parity, one stop bit, and no handshake.

```visualbasic
Interface1.S1.SetSerialParameters(
  _SERIAL_MODE_RS232,
  9600,
  8,
  _SERIAL_PARITY_NO,
  _SERIAL_STOPBITS_ONE,
  _SERIAL_FLOWCONTROL_NONE)
```

Channel S1 is in RS232 mode, 9600 bits per second, 8 data bits, no parity, one stop bit, hardware flow control RTS/CTS.

```visualbasic
Interface1.S1.SetSerialParameters(
  _SERIAL_MODE_RS232,
  9600,
  8,
  _SERIAL_PARITY_NO,
  _SERIAL_STOPBITS_ONE,
  _SERIAL_FLOWCONTROL_RTSCTS)
```

Channel S1 is in RS232 mode, 9600 bits per second, 8 data bits, no parity, one stop bit, software flow control by XON and XOFF.

```visualbasic
Interface1.S1.SetSerialParameters(
  _SERIAL_MODE_RS232,
  9600,
  8,
  _SERIAL_PARITY_NO,
  _SERIAL_STOPBITS_ONE,
  _SERIAL_FLOWCONTROL_XONXOFF)
```

# WaitForData

This command works the same way as the _Serial command  WaitForData.

# **_GeneralIO channel commands**

# Close

This command works the same way as the _GeneralIO command  Close.

# ClosePulse

This command works the same way as the _GeneralIO command  ClosePulse.

# GetVoltage

This command works the same way as the _GeneralIO command  GetVoltage.

# IsClosed

This command works the same way as the _GeneralIO command IsClosed.

# IsPullupOn

This command works the same way as the _GeneralIO command IsPullupOn.

# Open

This command works the same way as the _GeneralIO command Open.

# PullupOff

This command works the same way as the _GeneralIO command PullupOff.

# PullupOn

This command works the same way as the _GeneralIO command PullupOn.

# WaitWhileVoltageInRange

This command works the same way as the _GeneralIO command WaitWhileVoltageInRange.

# **_Ir channel commands**

# IrSend

This command works the same way as the _Ir command IrSend.

# Send

This command works the same way as the _Ir command Send.

# SetCarrier

This command works the same way as _Ir command SetCarrier.

# SetSerialParameters

The function sets the communication parameters of the IR channel.

#### Syntax

```visualbasic
Function SetSerialParameters(
  mode As Byte,
  bitspersecond As Long,
  databits As Byte,
  parity As Byte,
  stopbits As Byte,
  flowcontrol As Byte,
  ParamArray)
As Boolean
```

#### Parameters

mode

Byte It is the mode of the channel. Predefined constants for parameter mode are as follows:

|  |  |  |
| --- | --- | --- |
| Name | Value | Description |
| _SERIAL_MODE_RS232 | 0 | Channel is in RS232 mode. |

bitspersecond

Long Following baudrates can be used: 1200, 2400, 4800, 9600, 19200, 38400,                    57600, 115200.

databits

Byte It is the number of data bits from 7 to 8.

parity

Byte It is the type of parity. Predefined constants for parameter parity are as follows:

|  |  |  |
| --- | --- | --- |
| Name | Value | Description |
| _SERIAL_PARITY_NO | 0 | No parity. |
| _SERIAL_PARITY_ODD | 1 | Odd parity. |
| _SERIAL_PARITY_EVEN | 2 | Even parity. |

stopbits

Byte It is the number of stop bits. Predefined constants for parameter stopbits are as follows:

|  |  |  |
| --- | --- | --- |
| Name | Value | Description |
| _SERIAL_STOPBITS_ONE | 0 | One stop bit. |
| _SERIAL_STOPBITS_TWO | 2 | Two stop bits. |

flowcontrol

Byte It is the type of control. Predefined constants for parameter flowcontrol are as follows:

|  |  |  |
| --- | --- | --- |
| Name | Value | Description |
| _SERIAL_FLOWCONTROL_NONE | 0 | No handshake. |

ParamArray

It is not used in this function. It is there just to maintain compatibility with _Serial command SetSerialParameters.

#### Return value

Boolean It is True on success or False if an error occurs.

#### Example

Channel IR1 is in RS232 mode, 9600 bits per second, 8 data bits, no parity, one stop bit, and no handshake.

```visualbasic
IR1.SetSerialParameters(
  _SERIAL_MODE_RS232,
  9600,
  8,
  _SERIAL_PARITY_NO,
  _SERIAL_STOPBITS_ONE,
  _SERIAL_FLOWCONTROL_NONE)
```

# StopIrSend

This command works the same way as _Ir command StopIrSend.