Every device **shipped from the factory** is set according to the **Factory Default** column table below.

When pressing the **System Default (S.D.) button**, the system default function is performed according to the table below, the **System Default **column. The main purpose of this functionality is to regain connection to the touch panel with a lost password or unknown IP settings.

The System Default (S.D.) button **location **is typically described in the mechanical description of a specific unit. A thin screwdriver is needed to press of S.D. button. 

If you press S.D. button on controllers, so CPU LED indicator will flash to **confirm **the system default function.

|  |  |  |
| --- | --- | --- |
|  | **Factory Default** | **System Default** |
| Configuration | Identification | Magic name | controlCUE-x-x_  
CS0000.R00.000000 | Not changed |
| IP settings | DHCP | On | On |
| IP address (alternate) | 192.168.1.127 for controllers<br>192.168.1.128 for touch panels | 192.168.1.127 for controllers<br>192.168.1.128 for touch panels |
| Subnet mask | 255.255.255.0 | 255.255.255.0 |
| Default gateway | 192.168.1.1 | 192.168.1.1 |
| DNS | Primary DNS server | Empty | Not changed |
| Secondary DNS server | Empty | Not changed |
| Date and time | Date and Time | Day, month, year | Real | Not changed |
| Hour, minute, second | Real | Not changed |
| Time zone | (GMT+1:00 CET/CEST Belgrade,..., Prague) | Not changed |
| Internet clock | Use Internet clock | Not | Not changed |
| Primary NTP server | Empty | Not changed |
| Secondary NTP server | Empty | Not changed |
| Applications |  |  | Empty | Not changed |
| File storage |  |  | Empty | Not changed |
| System | Firmware |  | Current version | Not changed |
| Password |  |  | Empty | Empty |