title: "The setup procedure"
canonical: "https://docs.cuesystem.com/space/TOSASG/273547396/The%20setup%20procedure"
format: markdown
---
In order to set the workplace reservation system, it is necessary to perform the following steps:

1. Install occupancy sensor in the room. Route low-voltage cable from the occupancy sensor to the controller where the touchONE-sensor-app is running.
2. Connect sensor dry contacts to the controller’s versatile ports.
3. Connect power supply for the sensors.
4. Connect the controller to the network. If your switches do not support PoE (standard IEEE 802.3af, Class 0), then connect the stand-alone power supply (24 V DC) to the controller or use a PoE adapter.
5. Do the basic setup of the controller (IP settings, date, and time) using [Admin Web](https://docs.cuesystem.com/space/TOUAW/274563094).
6. Upload touchONE-sensor-app to the controller using Admin Web.
7. Set up the sensors (name, timeout, active dry-contact state).
8. Assign sensors to individual rooms. This is done in the reservation system settings and is described in the [Essential Setup](https://docs.cuesystem.com/space/TES) or [touchONE-manager On-premises Administration](https://docs.cuesystem.com/space/TOA) setup guides.