These installation instructions are intended for the following models 

- touchONE-10-W
- touchCUE-10-W

> ⚠️ The adhesive foil not only has an aesthetic purpose, so that the back of the panel is not  
> ⚠️ visible behind the glass, but also significantly increases the bonding strength of the  
> ⚠️ panel. Therefore, the use of adhesive foil is mandatory.

**Mounting Components**

![Mounting_components.png](media://e7097c30-4273-467d-8ffa-772b91a40393)

|  |  |
| --- | --- |
| ![Need_tools.png](media://b76b1dd8-54f2-40fb-a2a6-3a4072f84c3b) | **You will need:**<br>- ruler,
- pencil,
- scissors,
- squeegee,
- Allen key |
| ![Degreasin_option.png](media://745150dd-58d0-49e1-b2a3-88bdaf36deba) | **Degreasing option:**<br>- Cleaner Sachet or IPA and paper napkin<br>You need 3 cleaner sachets for cleaning (glass wall, foil, and the mounting adapter) |

**Installation instructions**

|  |  |
| --- | --- |
| ![1_Recommend_height.png](media://caa5af42-6c27-4346-a619-e34f5fe3be5d) | **Recommended height:**<br>- **LANDSCAPE  mount 1560 mm**
- **PORTRAIT mount 1610 mm**<br>**Mark the top of the foil** at such a height that the centre of the panel is at the recommended height of 1500 mm from the floor. |
| ![2_Clean_surface.png](media://b9fab7b1-ebed-4c32-ada1-a6709be5b374) | > ⚠️ Clean the surface with the Cleaner Sachet or IPA |
| ![3_Release liner.png](media://f4d07bb1-acd9-421c-8cc7-5f26afb4f404) | **Cut off** the strip along the edge of the release liner. |
| ![4a_Adhesive_foil_landscape.png](media://36bbc90a-7d8d-44f8-8076-594c9fb448f3)<br>![4b_Adhesive_foil_portrait.png](media://b445cb66-17a3-4936-88c5-24f446cd9417) | Use vertical ruler or level to **adjust correct foil vertical position**. Put foil on the wall with the release liner (not with adhesive part) to the ruler or level.<br>**Stick the adhesive part** of foil using delivered squeegee. |
| ![5_Stick the foil.png](media://2444be8c-95fa-4d5b-8398-66346551420f) | **Gradually remove** the release liner and stick the rest of the foil using a squeegee. |
| ![6_smooth_Centre outward.png](media://8576cf32-2995-4267-85fa-9672fc1a83ac) | To prevent air bubbles from forming under the film, squeegee lengthwise from the center outward using overlapping strokes. |
| ![7_Loosen screws.png](media://712863c8-3133-4b6d-992c-0d93100dcb18) | **Loosen the fixing screws** using the Allen key. |
| ![8_Remove_mounting_adapter.png](media://5b4f24a0-a4da-4bec-94d8-c291a90bcb3b) | Remove the back mounting adapter from the panel. |
| ![9_Clean_mounting_adapter.png](media://1d0c8daa-5dc0-4956-bd2c-6931d55b2c94) | > ⚠️ **Clean and degrease** the surface of the mounting adapter with the Cleaner Sachet or IPA |
| ![10_Attach_strips_of_tape.png](media://6ea1d8bc-b0fe-4a0e-95c5-aabdc9119583) | Attach six double-sided adhesive tapes to the rear side of the mounting adapter (wall-facing side).<br>- The long strips should be located along the top and bottom edges of the mounting adapter.
- The short strips should be located in the middle of the mounting adapter.<br>Stick the adhesive side of the tape with the squeegee. |
| ![11_clean_foil.png](media://2c5acd33-7f20-4f72-9cde-cd7e60931028) | > ⚠️ **Clean and degrease** the surface of the foil with the Cleaner Sachet or IPA |
| ![11_Remove_protective_film.png](media://0da830ce-feb2-42bc-87fb-3fdefd865355) | Remove the release liner from the adhesive tape. |
| ![12_instal_adapter.png](media://336e8019-fa91-417a-bd7b-baf17e05fe0c) | **Check the foil attached to the wall and make sure it is degreased and completely dry.**<br>Carefully attach the mounting adapter to the foil installed on the wall. |
| ![13_Wait_24h.png](media://d12e818b-6d43-43e5-bf87-87d9dd7a9041) | > ⚠️ **It is recommended to wait at least 24 hours, but preferably 72 hours, before proceeding to the next step (installation of the panel itself) to achieve maximum bond strength**. |
| > ℹ️ After applying the **adhesive tape**, the bond strength will increase as the adhesive spreads across the surface (also known as “wet-out”). 
> ℹ️ 
> ℹ️ - **At room temperature**:
> ℹ️   - **50%** **of the ultimate bond strength will be achieved after 20 minutes, **
> ℹ️   - **90% after 24 hours, **
> ℹ️   - **100% after 72 hours. **
> ℹ️ - This process occurs more **quickly at higher temperatures** and **more slowly at lower temperatures**.
> ℹ️ - **Ultimate bond strength can be achieved more quickly** (and in some cases, bond strength can be increased) **by exposing the bond to elevated temperatures** (e.g., 66°C [150°F] for 1 hour). This can improve adhesive wetting on the substrates.
> ℹ️ - Abrading the surfaces or using primers/adhesion promoters can also increase bond strength and help achieve ultimate bond strength more quickly. |
| ![14_Remove_cover.png](media://66be8790-066e-4ae3-840d-061f8dc1b6bf) | Remove the cable bushing cover at the point where you want to route the cable.<br>It is possible use four different variants. |
| > ℹ️ **When installing cable, use flexible flat or round cables with a maximum diameter of 5 mm. CAT5 and CAT5e category cables are sufficient for proper panel functionality.**
> ℹ️ 
> ℹ️ **Cables of higher categories have too large a diameter, a large allowable bend radius, and are not flexible enough for easy panel installation.** |
| ![15_Cable_routing.png](media://f7c92c11-7618-417a-b441-671b07872917) | Install cable to the selected route through the selected bushing. Cable length inside depend on the variant that will be used. Covers for unused bushings are delivered.<br>**Connect Ethernet cable** to the panel |
| ![16_instal_panel.png](media://bb9f56e5-4ab9-44a3-97f7-c34de9dbb8f5) | Place the panel onto the mounting adapter by clicking it into adapter, which will cause the magnets to connect. |
| ![17_fixing screws.png](media://81fabde0-9884-4d76-97c2-1b71002a20e4) | Carefully tighten the fixing screws with an Allen key.<br>We recommend tightening preferably all 4 screws. If there is difficult access to some of the screws, use at least 2 screws in opposite  
corners. The screws can be installed from the top or bottom, or from the sides, depending on the installation conditions. |